GENERAL
APF850 Series is designed in Oval Gear technology with digit display for totalizer & flow rate and providing scale pulse and analog output 4-20mA. APF850 series Oval Gear flowmeter are both high accuracy and easily adaptable to most industrial applications.
Features
15 – 40 mm (1/2″-1-1/2″””)lines sizes
Handles viscosities up to 50000 CP
Wide range of application
Various process connection types available
5 digit Totalizer (Resettable)/ 8 digit Totalizer (LCD)
4-20 mA or pulse output
High accuracy of +/-0,5% of reading or (+/-0.2% of reading)
Display with auto sleep function that gets up to 6 years of battery life
Standard Specification
- Size : 15, 20, 40 mm
- Flow Range : 5-500 L/Hr
- Accuracy :
+/-0.5% of reading (Standard)
+/ -0.2% of reading (option) - Repeatability : +/-0.1% reading
- Material
Body, Cover & Flange : Cast Iron/ Stainless Steel 316
Roots : Polyphenylene sulfide (PPS)
O-Rings : PTFE
Register Housing : Aluminium Alloy - Max. Viscosity
0.3-200 CP (Standard)
201-50000 CP (Optional) - Operating Temperature
-10 to 120°C (Standard)
-10 to 150°C (Optional) - Max. Pressure 19 Kg/cm2
- Process Connection :
Thread : NPT (Male) with coupling
Flange : JIS 10K FF/ ANSI 150#FF - Power Supply : 3.6 V Battery, Size D x 1 ea
- Battery Life : 3-6 years
- Protection Class :
IP 65
Intrinsically Safe (Unscaled) - Flow Range
- 15S mm : 5-200 L/Hr @5CP
- 15 mm : 10-700 L/Hr @5CP
- 20 mm : 20-1300 L/Hr @5CP
- 25 mm : 50-3500 L/Hr @5CP
- 40 mm : 100-5000 L/Hr @5CP