Deskripsi Produk Super Rite Series 999 Meter
Super Rite Series 999 Meter
Detail Product :
- 3/4″ or 1″ NPT female inlet and outlet ports
- Recommended fo 5 to 20 GPM (19 to 76 LPM) Output 1±1% accuracy 150 PSI maximum pressure
- Meters fluid at temperature from -150°F (-20°C) to 150°F (66°C)
- Weatherproof, corrosin resistant
- Zero reset unit whells have large 11/16″ figures
- Easy to read totalizer registers to 99.999.99 gallons
- Compact design -8″x6″x6″ (200 x 150 x 150 mm)
Counter Assembly
For acces to counter assembly, remove reset knob (item 3) by grasping edges and pulling firmly. Knob is held in place by a spring clip. Loosen two screws (item 29) and lift counterface (item 2) and cover (item1) off. Remove two screw (item 13) to extra counter (item 4). Reassemle by reversing produce.
Meter Chamber Assembly
To expose meter chamber assembly, tilt the meter at lest slighty, so that parts fall out when removing meter housing. Remove the four screws (item 20), then remove meter housing (item 19). Meter chamber assembly consists of upper and lower chambers, a nutating disc and seal gasket. Reassemble by reversing procedure.
If replacement of any components of the meter chamber assembly is required the complete assembly must be replaced due to the precise method of its construction,. This assures a proper fit and a correctly operating chamber.
Calibration
The Super-Rite Series 80°C meters can be calibrated for either U.S. gallons or liters. Calibration is required after disasembly wear. Depending on the model, series 80°C meters are calibrated at the factory, metering stoddard solvent in either U.S. gallons or liters. Meter calibration can be easily changed by following the calibration procedure listed below. A proving container or a container of KNOWN volume will be needed for the calibration procedure. It is recommended that the containeris volume be at least five times larger than the unit of calibration. For example, a five galon container should.