Lutron GCH-2018 CO2 Meter

Detail Luftron GCH-2018 CO2 Meter :

  • NDIR method principal for C02 (Carbon dioxide) measurement, available for long term operation
  • High repetability and high accuracy
  • Two probes, one is for CO2/ temp. measurement, the other probe is for humidity/ Temp/ Dew point measurement
  • Seperate probe, easy operation and convenient for remote measurement
  • CO2 function with alrm setting
  • Can set the attitude (height) value with default for compensation
  • Humidity measurement eith alarm setting
  • Can set the attitude (height0 value with default for compensation
  • Humidity measurement eith fast response time
  • Large S-TN LCD, high contrast, easy readout
  • Data hold function th freezing the desired value of display
  • Records maximum and minimum readings with recall
  • RS232/USB computer interface
  • Microprocessor circuit assures maximum possible accuracy, provides special functions and features
  • Heavy duty and compact housing with head carrying case, designed for easy carry out and features
  • Auto shut off is available to save battery life
  • Power supply from batteries or DC 9V adapter in

Specifications :

  1. Circuit : Custom one – chip of microprocessor LSI circuit
  2. Display ;
    LCD size : 52×38 mm
    dual function LCD display
  3. Measurement : CO2 (carbo dioxide) temp, Humidity, dew point, temp
  4. Unit :
    CO2 : ppm
    Humidity : % RH
    Dew point : °C °F
    Temp : °C °F
  5. Response time : CO2
    – 2 Min, typically
    – Reach the 63% reading value
    – Depend the environment air circulation
  6. CO2 Altitude (Height) value setting : 0 to 9.000 meters (for precision measurement altitude (height) value for the conpensation)
  7. Temp. conpensation : Automatic temp. conpensation
  8. Advanced setting :
    Auto power off enable/ disable setting
    °C °F setting
    CO2 alarm value setting
    CO2 altitude value setting
  9. Alarm setting : For CO2 measurement only
  10. Data hold : Freeze the display reading
  11. Memory recall : maximum and minimum value
  12. Display sampling time : Approx 1 second
  13. Power off : Auto shut off saves battery life. Or manual off by push button
  14. Data output : RS 232/ USB PC serial interface
    – Connected the optional RS232 cable UPCB-02 will get the RS232 plug
    – Connect the optional USB cable USB-01 will get the USB plug
  15. Probes no. Two probes :
    – Probe 1 is for CO2 temp, measurement
    – Probe 2 is for humidity, Dew point. Temp measurement
  16. Operating temp : 0 to 50°C
  17. Operating humidity :
    Main instrument : Less than 85% R.H
    CO2 probe : Less than 85% RH
    Humidity measurement : 0 to 95% RH
  18. Power supply : 1.5 V battery (UM-3, AA) x 6 PCs, or equivalent
  19. power current :
    CO2 measurement :
    – Approx DC 9.6 mA for 90% period
    – Approx DC 128 mA 10% period
    Humidity measurement ; Approx DC 5.6 mA
  20. Weight :
    Main instrument : 372g/ 0.82 LB (including battery)
    CO2 probe : 158g/ 0.35 LB
    Humidity probe : 82g/ 0.18 LB
  21. Dimension :
    Main instrument : 173x68x42 mm
    CO2 probe : 185x38x26 mm
    Humidity probe : 200x23x19 mm