Infrared Thermometer LUTRON TM-939

Detail LUTRON TM-939 Infrared Thermometer
Features :

  • -20°C to 650°C wide range temperature measurement
  • Infrared thermometer, non-contact temperature, measurement, -20°C to 650°C (4°F to 1202°F), precision for none contact temperature meassurement
  • Emssivity adjusment for IR thermometer
  • Laser quide for IR thermometer
  • 2 in 1, infrared thermometer + thermocouple (type K/J/T/E/R) thermometer
  • Thermocouple probe accepts 5 different types : types K, type J, Type T, Type E, Type R
  • Microcomputer circuit with high performance
  • Built in °C & °F select button on the front panel
  • Data hold function for stored the desired value on display
  • Memory function to record the maximum and minimum reading eith recall
  • Build the REL button, useful for relative measurement
  • Sensor select button on the front panel easy to change different type probe
  • RS 232 data output, easy cooperate with computer
  • Optional data acquisition software for data record
  • Auto power shut off saves battery life
  • Built-in low battery indicator
  • Heavy duty and compact housing case with stand
  • 006P DC 9V battery power supply

General Specifications :

  • Display : 51 x 32 mm super large LCD display, 15 mm (0.6 inch) digit size
  • Measurement :
    – Infrared thermometer (non contact temperature measurement)
    – Thermocouple probe, type K/J/T/E/R
  • Function ; °C °F, data hold, memory (max. min) relative measurement, emissivity adjusment (IR thermometer)
  • Resolution : 1 degree or 0.1 degree
  • Circuit : Exclusive microcomputer circuit, the software build in linearity correction instead the traditional hardware circuit
  • IR Emissivity adjusment :
    Range : 0.20 to 1.00
    Adjusment by pushing button on front panel
  • IR sensor : Thermocouple pie
  • R measure wave length region : 6 to 12 micro meter
  • IR distance factor : D/S ratio : approx 7:1 (D=distance, S=Spot)
  • Laser guide : Red laser light, less than 1 mW, Meet EN60825
  • Probe input socket : Thermocouple probe : standard 2 pin thermocouple
  • Sampling time : Approx 1 second
  • Memory recall : Memorize the maximum, minimum reading with recall
  • Offset adjustment : for thermocouple thermometer offset adjustment by pushing button on front panel
  • Over indications : Show “—“
  • Data output : RS232 PC serial interface
  • Power supply : Alkaline or heavy duty type, DC 9V battery, 006P, MN1604 (PP3) or equivalent
  • Power consumption :
    Approx . DC 10 mA (Laser guide off)
    Approx. DC 19 mA (Laser light on)
    – Above consumption value is calculated under the function of IR thermometer
  • Operating temp : 0 to 50°C (32 to 122°F)
  • Operating humidity : Less than 80% R.H
  • Dimension : 220 x 68 x 30 mm
  • Weight : 220 g/ 0.4 LB

Leave a Reply