Pressure Gauge WIKA Model 101.00 and 101.12

Description

Model 101.00, 101.12 are mechanical pressure gauges with a plastic capallary. These instruments are based on the proven Bourdon tube measuring system. The plastic case is available in nominal sizes of 27 mm and 40 mm.

Features of the plastic capilary

Due to the length and flexibility of the capilary, the mounting position of the indictor can be independent of the measuring point. Through the use of a specific plastic, the long-termm resistance of the capillary is also maintened at high temperatures. An advantage of plastic capillaries, as against copper capillaries, is that these do not need to be bent or coiled. Thus, the plastic capillary makes installation much easier and eliminates the risk of any fatigue fracture.

Application area in heating technology

These instruments are particulary suitable for application in the heating industry. The suitability of the instrument was confirmed in long-term test under chracteristic application conditions.

Individual Customer Variants

Based o many years of experience in manufacturing and development, WIKA is also happy to offer customers-specific solutions. The G 1/4 B standard process connection can, on request, also be completed with a plastic sealing ring at the thread. This eliminates the time-consuming-specific process connection design, WIKA also offers the development of plastics plug connections to meet the requirement.

Application

For heating equipment

Special Features

  • Process connection : G 1/4 B or plug connection
  • Scale ranges : 0.4 bar or 0.6 bar
  • Model 101.00 : very simple to install (snap-in-mounting)
  • No bending or coiling of capilary necessary
  • Suitability confirmed in long term test under chracteristic application conditions

Specifications

Design

Following EN 837 -1

Nominal size in mm

Model 101.00 : NS 40

Model 101.12 : NS 27

Accuracy class

Model 101.00 : 2.5%

Model 101.12 : 40%

Scale ranges

  • 0….4 bar
  • 0….6 bar

Pressure limitation

Steady : 3/4 x full scale value

Fluctuating 2/3 x full scale value

Short time : Full scale value

Permissible temperature

Ambient : -20……+60°C

Medium : +60°C maximum

Temperature effect

When the temperature of the measuring system deviates from the reference temperature (+20°C) max. ±0.4%/ 10 K of the span

Process connection

Via capillary, plastic (PE-LLD)

  • G 1/4 B threaded connection (bras and copper): optionally with PTFE sealing at the thread capilary length 300….2.000 mm
  • Plug connection (plastic), various versions capilarry length 260….2.000 mm