Description
Design
EN 837-3
Nominal size in mm
63, 100, 160
Accuracy class
1.6
Scale ranges
NS 63 : 0….40 mbar to 0….600 mbar
NS 100 : 0…..16 mbar to 0….600 mbar
NS 160 : 0…..2.5 mbar to 0….600 mbar
or all other equivalent vacuum or cpmbined pressure and vacuum ranges or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady : Full scale value
Fluctuating : 0.9 x full scale value
Permissible temperature
Ambient : -20…..+60 °C
Medium : +100°C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (20°C)
Max ±0.6%/10K of full scale value
Application
- With liquid-filled case of for applications with high dynamic pressure loads or vibrations
- For gaseous, dry and aggresive media, also in aggresive ambience
- Process industry : Chemical/ petrochemical, pharmaceutical, boitechnology, machine and power generation industries.
Special Features
- Zero adjustment at the front
- All stainess steel construction
- Special connection location on request
- Low scale ranges from 0…..2.5 mbar