Specification Flowrate up to 61.26 m3/hr with discharge pressure head up to 8.6 bar.
Advanced TM Series High Pressure WILDEN
Posted on Categories WILDEN Leave a comment on Advanced TM Series High Pressure WILDENDescription Flowrate up to 72.66 m3/hr with discharge pressure head up to 20 bar.
Original TM Series High Pressure WILDEN
Posted on Categories WILDEN Leave a comment on Original TM Series High Pressure WILDENDescription Flowrate up to 72.66 m3/hr with discharge pressure head up to 8.6 bar.
Advanced TM Series Plastic Bolted WILDEN
Posted on Categories WILDEN Leave a comment on Advanced TM Series Plastic Bolted WILDENSpecification Flowrate up to 47. 04m3/hr with discharge pressure head up to 8.6 bar.
Original TM Series Plastic Clamped
Posted on Categories WILDEN Leave a comment on Original TM Series Plastic ClampedDescription Flowrate up to 35.46 m3/hr with discharge pressure head up to 8.6 bar.
C101 Pressure Reducing Valves Socla
Posted on Categories SOCLA Leave a comment on C101 Pressure Reducing Valves SoclaDetail Produk : Data Sheet ukc101-low-rate Socla
Jual Pressure Reducing Valves Socla C102
Posted on Categories SOCLA Leave a comment on Jual Pressure Reducing Valves Socla C102Detail Produk : Data sheet ukc102_c102c
SOCLA CL301 CONTROL VALVE
Posted on Categories SOCLA Leave a comment on SOCLA CL301 CONTROL VALVEApplication and General Characteristic : It controls and maintains a preset upstream pressure regardless of variations in flow rate Always mounted in line, it prevents the pump from reducing its suction pressure below the security point. It prevents also from exceeding the pumping capacity when the demand is higher. Working Principal : When upstream pressure is getting lower than the pressure required by the pilot Q, the pilot will close and limit the flow circulation. The upstream pressure pushes on … Continue reading “SOCLA CL301 CONTROL VALVE”
SOCLA CL701
Posted on Categories SOCLA Leave a comment on SOCLA CL701Control Valve Altitude Float Operated Application and general chracteristics : It prevents from overflowing from overflowing and matains a constant level in the tank to a float Opening and closing are very progressive (a few centimeters from the required level) Prefer the installation at the bottom of the tank or close to it Working Principle The level in the tank is low and the float switch S is fully open. The valve A is wide open and supplies the tank. … Continue reading “SOCLA CL701”
SOCLA TYPE 895
Posted on Categories SOCLA Leave a comment on SOCLA TYPE 895DESCRIPTION Pressure PFA/PS in bar Ө 100° Body : GJL cast iron epoxy coated (DN 50 to 150) GJS ductile iron epoxy coated (DN200 to 400) Plates : Stainless Steel (304) Seal : EPDM Spring : Stainless Steel DN PFA PS Cat Ref UV “ mm water L1 L2 G1 G2 2 50 16 16 16 16 16 1 149B 3000 1 2 1/2 65 16 16 16 15 16 1 149B 3001 … Continue reading “SOCLA TYPE 895”