Main Cracteristics
Magnetic transmission
Maximum water temperature 40 °C
Removal measuring machanism
Insentive to upstream disruptive elements
3550 orientable register
high resistance to water be equipped with a removable bonnet for quick and easy mintenance
Equipable with an HRI Sensor
Applications
The 405S is a dry dial multijet water meter wuth a protected magnetic transmission between the measuring element and the totalizer. It is a PN 16 Meter suited to hard network conditions.
Its realibility resistance to bad water quality and noiseless operation will satisfy both end users and network managers.
Available Optioms
- Copper/glass register (standart or DN25 to 40)
- HRI electronic sensor (pulse unit or data unit) for DN 15 – 40
- Cu/Glass register for DN15 & 20 meters non return valve
Accuracy
The specisl dedign of this meter combined with the precision of the plastic parts injected by own. Sensus injection deparment results in an accuracy curve exceeding the requirements for the ISO 4064 standart.
The meter will remail its metrological characteristics even if it is subject to bad water quality charged with sand or other particless.
Reliability
Larger particles present in water can be filtered first by the tubular stainer, then by the seat stainer. The smallest particles can go throught the neter without damage.
All the gears are situated in the dry part of the meter (totalozer0, which removes any risk of blockage due to suspended matter in the water.
the 405S water meter keeps its metrological accuracy for many years of operation, even in very difficult working conditions
Legibility
The display on 8 drums (5 for m3, 3 for decimals) and 1 pointer ensures perfect readability. The lowest resolution is 0.05 litres. The dial has a cental disc whose rotation indicates the passage of water. This indicator can be used to reveal a downstream leak.
The plastic register casing equipped with a wiper for optimum legibility under all conditions. The 405S water meter operates in horizontal position and its dry dial can rotate up to 3550.
The dial can therefore be easily read under all conditions of use.
As an option, (standard for DN25 to 40 meters), The meter can be supplied with a cupper-glass register, making it perfectly water – tight (IP 68)
Marking
An arrow on both sides of the body shows the directions of flow.
The years of manucfatucture the individual meter number are engraved to the cover.
The manufacture’s name, the type of meter, the nominal flowrate, the metrological class and the EC patter approval number are printed on the dial.
Installation and operating instructions
The 405S meter must be installed in a low point of the pipeline, with the arrow cast on the body showing direction of the water flow. Before fitting the water meter, all pipework must flushed out to remove all impurities.
An upstream stop valve is recomended to allow installation and removal of the water meter.
When connecting the meter with the water network, the upstream valve must be opened slowly so that the water fills the meter as smoothly as possible.
No spesial maintenance required.
Technical Cracteristics
Metrological cracteristic – EEC Directive 75/33
Nominal Flowrate (Qn) | 6 m3/h |
Maximum Flowrate (Qmax) | 12 m3/h |
Minimal Flowrate (Qmin) | 120 l/h |
Transition Flowrate (Qt) | 480 l/h |
Operation Charactristics | |
Starting Flowrate | 20 l/h |
Minimum Flowrate ±5% | 90 l/h |
Transtional Flowrate ±2% | 180 l/h |
Maximum registration | 105 m3 |
Lowest resolution | 0.05 lh |
Pressure loss at | 0.85 bar |
Working Pressure | 16 bar |
Sizes and Weight | |
Length | 260 mm |
Width | 102 mm |
Total Height | 142 mm |
Height from base centreline | 48 mm |
Theread | diameter 48 mm |
Theread | 2.309 mm |