Tokico oil flowmeters are displacement type flow meter which are used a wide variety of applications including measuring of boiler fuel oil and diesel oil, as well as for transactions for kerosene, light oil and heavy oil.
FRO Type
This Flow meter is widely used for transaction and in other applications is which a Roots type flowmeter is most suitable.
The Roots rotor rotates without physical contact, resulting in extremely low pressure loss. In addition, its accuracy remain virtually unchanged a long period of time.
Features :
- Wide flow range and high accuracy
The accuracy of these flowmeters is within ±5% over a wide range of flow rates (max range of 1 : 50 for heavy oil) - Small pressure loss
Because the pressure loss of these meters is low, it is posibble to perform accurate measuring at the suction side of a pump as well as accurate measurement of high viscocity fluids. - Compact Design
A positive displacement type flowmeter can used at relatively high rotating speeds, making for compact design. In addition, the counter unit of these meters is compact yet easy-to-read and construction is simple - Excellent durability
The simple construction of these meters makes for longterm durability with virtually no degration of accuracy. - An electrical transmitter unit attachable
A microswith or a read switch type tansmitter unit having simple construction and high reliability is available.
Specification :
Model | FRO Type |
Bore | 50 mm |
Model No. direct-reading integrating type | FR00541-02X |
Accuracy | ±0.5% |
Max. working pressure | 10 kgf/cm2 |
Hydraulic test pressure | 20 kgf/cm2 |
Flow Range kerosene, Light Oil | 1.500 – 9.000 l/h |
Max. working temperature | 50°C for kerosene and light oil (100°C with the FGB type) 100°C for heavy oil (120°C with the FGB-00X and FGB-02X types) |
Flange Rating | JIS 10kgf/cm2FF |
Material Body | Cast Iron (FC25) |
Material rotor | FRO type (Aluminium alloy casting) |
Counter Unit | Integrating pointer and integrating counter ( a reset counter is also available) |
Electrical Transmitter Unit | |
Transmitter | FRO type : microswith (M) |
Power Supply | AC100V 50/60 Hz as standard |
Number of Pulse | 0-5 PPS |
Output signal | ON-OFF contact |
Transmission cable | 2-wire cable with cabtype |
Normal Operation | |
Kerosene, Light Oil | 1.500 – 13.000 (Viscosity Intermittent), 1.500-9.500 (Viscosity continous) |
A heavy Oil | 250-15.000 (Viscosity Intermittent), 250-13.000 (Viscosity continuous) |
Max | |
Kerosene, Light Oil | 15.000 |
A heavy Oil | 17.000 |