Flow Meter Tokico FGBB423BAL-02X 15 mm

Tokico oil flowmeters are positive displacement type flow meter which are used in a wide variety of applications including measuring of boiler fuel oil and diesel oil, as well as for transactions for kerosene, light oil and heavy oil.

FGB Type

This flowmeters employs gear-type rotor for small volume flow of low-viscosity oil in heat control applications, etc. It can be used without modification to measure kerosene, light oil or heavy oil. Measuring accuracy is ±0.5%

Features :

  • Wide flow range and high accuracy
    The accuracy of these flowmeters is within ±0.5% over a wide range of flow rates (max range of 1 : 150 for heavy oil)
  • Small pressure loss
    Because the pressure loss of these meters is low, it is posibble to perform accurate measuring at the suction side of a pump as well as accurate measurement of high viscosity fluids
  • Compact Design
    A posive displacement type flowmeter can be used at relatively high rotating speeds, making for compact design. In addition, the counter unit of these meters is compact yet easy-to-read and construction is simple.
  • Excellent durability
    The simple construction of thes makes for longterm durability with virtually no degradation
  • An electrical transmitter unit attachable
    A microswitch or a reed switch type transmitter unit having simple construction and high reliability is available

Specification Product :

ModelFGB Type
Bore15 mm
Model No. direct-reading integrating typeFGBB423BAL-00X/02X
Accuracy ±0.5%
Max. working pressure10 kgf/cm2
Hydraulic test pressure20 kgf/cm2
Max. working temperature50°C for kerosene and light oil (100°C with the FGB type) 100°C for heavy oil (120°C with the FGB-00X and FGB-02X types)
Flange RatingJIS 10kgf/cm2FF
Material BodyCast Iron (FC25)
Material rotorFRO type (Aluminium alloy casting)
Counter UnitIntegrating pointer and integrating counter ( a reset counter is also available)
Electrical Transmitter Unit 
TransmitterFGB type : Reed Switch (S)
Power SupplyAC100V 50/60 Hz as standard
Number of Pulse0-5 PPS
Output signalON-OFF contact
Transmission cable2-wire cable with cabtype
Normal Operation 
Kerosene, Light Oil10-200
A heavy Oil5-200