Main Characteristics :
Patended hydrodynamically balanced rotor
Patended metrical calibrations adjusment
Hermetically sealed register (IP 68)
Register may be rotated through 360°
High overload capability
Removable measuring element
Up to 3 pulsers (1 x OD, 2 x RD) may be fited without breaking the approval seal
Powder coating affords maximum corrosion protection
Application :
Flow sensor for heat meter for commercial and light industrial use DN 50 bis 150 for customer billing
For measurement of hot process water up to 130°C
For high permanent flow rate such us as generated by pumps, as well as for the measurement of low flow rates in off-peaks periods.
Installation in horizontal and vertical pipe lines.
Performance Data WP – Dynamic 130°C
Nominal Diameter | DN 100 |
(Qmax)Max.Peak Flow once in the life time 24 h Qmax or 5 Min.1.2 x Qmax | 140 m3/h |
(Qn) Continuous Flow (±2%) | 70 m3/h |
(Qt) Transitional Flow (±2%) | 4.8 m3/h |
(Qmin) Minimum Flow (±2%) | 2.0 m3/h |
(Qmin) Starting Flow | 0,6 m3/h |
Performance data table according to Din EN 1434
Nominal Diameter | DN 100 |
(qs) Overload Flowrate | 120 m3/h |
(qp) Continuous Flow Horizontal | 60 m3/h |
(qih) Minimum Flow Horizontal | 2.4 m3/h |
(qiv) Minimum Flow Vertical | 6 m3/h |
(qp/qi) Ratio Horizontal | 25 |
(qp/qi) Ratio Vertical | 10 |