Detail LUTRON YK-2005AH Hot Wire Anemometer
- Combination of hot wire and standard thermistor, deliver rapid and precise measuerement event t low air velocity value
- Slim probe, ideal for grilles and diffusers
- Air velocity ; m/S, Ft/min, Km/h, Knots, Mile/h
- Air flow :CMM (m^3/min) and CFM (ft^3/min)
- Air temperature (°C, °F)
- Type K/J thermocouple thermometer
- Real time data logger, build in clock (hour-minute-second-year-month-date)
- Auto data record 16.000 Data logger no
- Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds
- Zero adjustment
- Can default auto power off or manual power off
- Can default the air velocity, air flow, temp.unit
- Air flow measurement can set the are dimension
- Large LCD with multiple display
- Data hold, record max and min reading
- Microcomputer circuit provides special function and offer high accuracy
- Air temp. user thermistor sensor fast response time
- Power by UM3 (1.5V) x 4 batteries or DC 9V adapter
- RS232 PC serial interface
- Seperate probe, easy for remote measurement
- Applications : Environmental testing, air convenyors, Flow hoodsm clean rooms, Air velocity, Air balancing, Fans/ motors/ blowers. Furnace velocity, Refrigerated case, Paint sparay booths.
General Specifications :
- Circuit : custom one – chip microprocessor LSI circuit
- Display : LCD size : 58 x 34 mm
- Measurement unit :
Air velocity m/S, Ft/ min, Km/h, knots, Mile/h, Air flow : CMM (m^3/ min) and CFM (ft^3/min)
Air temperature (°C, °F) - Sampling time of data logger : 2 sec 8 hour 59 min. 59 sec@Auto data logger
- Sensor structure :
Air velocity and air flow : Tiny glass bead thermistor
Air temperature : Thermistor
Type K/J thermometer : Thermocouple - Temperature conpensation : Automatic temp. conpensation fot the type K/J thermometer
- Data hold : freeze the display reading
- Memory recall : maximum and minimum value
- Sampling time of display : Approx 1 second
- Power off : Auto shut off saves battery life or manual off by push button
- Data output : RS232 PC serial interface
- Operating temperature : 0°C to 50°C
- Operating humidity : max 80% RH
- Power supply (clock module) : DC 3V silver battery Type : CR2032
- Power current :
Approx DC 21.5 mA (Main instrument)
Approx DC 70 mA (Main instrument + Hot wire with probe) - Weight : 515g/ 1.13 LB (battery included)
- Dimension :
Main instrument : 20 x 76 x 38 mm
Telescope : *Round, 12 mm Dia x 280 mm (min length)*
Round 12 mm Dia x 940 mm (maxlength)