LUTRON YK-2005TM THERMOMETER

Detail LUTRON YK-2005TM THERMOMETER :

  • 3 in 1, Thermocouple (type K/J) thermometer, Pt ohm thermometer + infrared thermometer
  • 0.1 degree resolution for Pt 100 ohm and type K/J
  • Wide temp, measuring range
  • 4 wires PT 100 ohm probe input, 0.00385 alpa coeeficient, meet DIN IEC 751 high precision
  • Offser adjustment
  • Fast humidity measuring response time
  • Real time data logger, build in clock (hour, -min, -sec, -year,-month)
  • Auto or manual data record 16.000 data logger no
  • Wide sampling time adjutment range from two seconds to 8 hours 59 minutes 59 seconds
  • RS232 computer interface
  • Can default auto power off or manual power off
  • Multifunction with easy operation
  • Large LCD with multiple display
  • Data hold, record max and min reading
  • Microcomputer circuit provides special function and offer high accuracy
  • Power by UM3 (1.5V) x 4 batteries or DC adapter
  • RS232 PC serial interface
  • Seperate probe, easy for operation of different measurement environment

General Specifications :

  • Circuit : Custom one-chip of microprocessor LSI circuit
  • Display : LCD size 52 x 34 mm
  • Measurement :
    – Themocouple probe (type K/J)
    – Platinum Pt 100 ohm (0.00385 alpha coefficient meet DIN IEC 751)
    – Infrared thermometer
  • Displau unit : °C or °F
  • Resolution : 0.1°C, 0.1°F
  • Sampling time data logger :
    Auto : 2 second to 8 hours 59 minutes and 59 seconds
    Manual : Push the data logger button once will save data one time (set the sampling time to 0 second)
  • Temp. Compensatuion : Automatic temp. compensation for the type K/J thermometer and infrared thermometer
  • Linear conpensation : Both for type K/J Pt,100 ohm and the IR thermometer
  • Offset adjustment : Availabe to adjust the zero drift value, adjustemt by pushing button
  • Probe input socket :
    – Type K & J probe : Standard 2 pin thermocouple socket
    – Pt 100 ohm and IR probe : Ear exclusive socket
  • Over indication : show “—“
  • Data hold : Freeze the display reading
  • Memory calll : Min and max value
  • Sampling time : approx 1 second
  • Power off : auto shut off saves battery life or manual off by push button
  • Data output : RS 232 PC serial interface
  • Operating Temp
  • Operating humidity : Less than 80% R.H
  • Power supply (main instrument):
    – DC 1.5 V battery (UM3/AAA) x 4 Pcs (heavy duty type)
    – DC 9V adapter input (@ AC/DC power adapter is optional)
  • Power current : approx DC 21.5 mA (@ main instrument + type K/J (Pt 100) probe
  • Weight : 515 g/ 1.13 LB (including battery)
  • Dimension : 203 x 76 x38