Master Meter SATAM ZCM17 24

The Satam ” Master Meter’ product range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard thant can be used regularly to check and calibrate measuring instruments or measuring systems. With minimal deimension, it can easily be moved to several different sites without the requirement for lifting tools.
Equipped with an Equalis electronic register thar ensures linearization of measurements, it can be used with liquids of various viscosities without loss of accuracy.

Sector of application
Oil depots

For oi product nd loading stations for tank truck tank car and ships

Hydrocarbon transportation
Distribution of fuel oil or by road tanker

Aircraft refueling
Aircraft dispensers and aircraft fueling tankers

Army
Depot supplies and loading of trucks

Transport companies
Refueling of locomotives, truck and public transport

Marine applications
Refueling of ships

Mining sites
Refueling of truck or site machinery

Design of the master meter
Robust construction

Positive displacement meter with moving blades

Modular design
Available with mechanical or electronic register

Calibration for different viscosities
Supplied with one calibration certificate per each operating viscosity

Key points
Compact design

Calibration device of reduced weght and dimensions
possibility to move the ZCM 17 to different sites without the requirement for liftting tools

Sel powered technology
Functioning of the mechanical register version without any power supply

Modular design
Wide range of accessories to create your customized calibration device
Can be installed on a trolley as mobile calibration equipment

Stability and accuracy of measurements

Stable and accurate volume measurement witout any influence of installation position
Flowmeter manifold seperated from measurement chamber to eliminate any posibble influence of external mechanical stresses on measurement accuracy

Technical data-Master meter ZCM17 24

Application : Master dedicated to calibration of custody transfer volume measuring equipments
Max. Operating flow rate m3.h-L/mn-USGPM: 24-400-105
min. Operating flowrate m3/h-L/mn-USGPM: 2.4-40-10.5
Measured liquids : petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methy ester oil.
Connections : Flanges or dry coupling*2×3 m hoses8
Meter :
Diameter : 2″
PD meter : ZC17-24

Version ZCM 17 IM

RegisterElectronic register (Equalis). Total volume : 6 digits Secure storage of ZCM 17 calibration curves. Calculation of reference volume
Volume displayOperating volume, base volume
Flowrate displayIncluded
Calibration curve7 flowrate values with 2 values per flow rate. One per operating viscosity
Calculation of reference volumeAutomatic calculation
Temperature measurementPt 100
Pressure measurementLocal display
Drainage equipmentManual drainage pump with purge valve and 2 release valves
Operating conditions  
Pressure10 bar max
Viscosity50 cSt max
liquid temperatureStandard : -25°C to +55°C-Option : -40°C to +55°C
Metrological Performances 
Volume accuracy< ±0.5% with linearization
Volume repeatability< ±0.02%
Temperature accuracy< ±0.5°C