The Satam ” Master Meter’ product range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard thant can be used regularly to check and calibrate measuring instruments or measuring systems. With minimal deimension, it can easily be moved to several different sites without the requirement for lifting tools.
Equipped with an Equalis electronic register thar ensures linearization of measurements, it can be used with liquids of various viscosities without loss of accuracy.
Sector of application
Oil depots
For oi product nd loading stations for tank truck tank car and ships
Hydrocarbon transportation
Distribution of fuel oil or by road tanker
Aircraft refueling
Aircraft dispensers and aircraft fueling tankers
Army
Depot supplies and loading of trucks
Transport companies
Refueling of locomotives, truck and public transport
Marine applications
Refueling of ships
Mining sites
Refueling of truck or site machinery
Design of the master meter
Robust construction
Positive displacement meter with moving blades
Modular design
Available with mechanical or electronic register
Calibration for different viscosities
Supplied with one calibration certificate per each operating viscosity
Key points
Compact design
Calibration device of reduced weght and dimensions
possibility to move the ZCM 17 to different sites without the requirement for liftting tools
Sel powered technology
Functioning of the mechanical register version without any power supply
Modular design
Wide range of accessories to create your customized calibration device
Can be installed on a trolley as mobile calibration equipment
Stability and accuracy of measurements
Stable and accurate volume measurement witout any influence of installation position
Flowmeter manifold seperated from measurement chamber to eliminate any posibble influence of external mechanical stresses on measurement accuracy
Technical data-Master meter ZCM17 24
Application : Master dedicated to calibration of custody transfer volume measuring equipments
Max. Operating flow rate m3.h-L/mn-USGPM: 24-400-105
min. Operating flowrate m3/h-L/mn-USGPM: 2.4-40-10.5
Measured liquids : petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methy ester oil.
Connections : Flanges or dry coupling*2×3 m hoses8
Meter :
Diameter : 2″
PD meter : ZC17-24
Version ZCM 17 IM
| Register | Electronic register (Equalis). Total volume : 6 digits Secure storage of ZCM 17 calibration curves. Calculation of reference volume |
| Volume display | Operating volume, base volume |
| Flowrate display | Included |
| Calibration curve | 7 flowrate values with 2 values per flow rate. One per operating viscosity |
| Calculation of reference volume | Automatic calculation |
| Temperature measurement | Pt 100 |
| Pressure measurement | Local display |
| Drainage equipment | Manual drainage pump with purge valve and 2 release valves |
| Operating conditions | |
| Pressure | 10 bar max |
| Viscosity | 50 cSt max |
| liquid temperature | Standard : -25°C to +55°C-Option : -40°C to +55°C |
| Metrological Performances | |
| Volume accuracy | < ±0.5% with linearization |
| Volume repeatability | < ±0.02% |
| Temperature accuracy | < ±0.5°C |