The Satam “Master Meter” product range is dedicated range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard that can be used regularly to check and calibrate measuring instruments or measuring systems. Within minimal dimensions, it can easily be moved to several different sites without the requirement for lifting tools.
Equipped with an Equalis electronic register that ensures linearization of measurements, it can be used with liquids of various viscosities without loss of accuracy.
Sector of application
Oil depots
For oil product reception and loading stations for tank truck tank car and ships
Hydrocarbon transportation
Distribution of fuel oil or fuel by road tankers
Aircraft refueling
Aircraft dispensers and aircraft fueling tankers
Army
Depot supplies and loading of trucks
Transport companies
Refuelling of lecomotives, truck and public transport
Marine applications
Refuelling of ships
Mining Sites
Refuelling of truck or site machinery
Desin of the master meter
Robust construction
Positive displacement meter with moving blades
Modular design
Available with mechanical or electronic register
Calibration for different viscosities
Supplied with one calibration certificated per each operating viscosity
Key point
Compact design
Calibration device of reduced weight and dimensions.
Possibility to move the ZCM 17 to different sites without the requirement
Self poered technology
Functioning of the mechanical register version without any power supply
Modular design
Wide range of accessories to create your customized calibration device
Can be intalled in a trolley as mobile calibration equipment
Stability and accuracy of measurement
Stable and accurate volume measurement without any influence of installation position
Flow meter manifold separated from measurement chamber to eliminate any posibble influence of external mechanical stressed on measurement accuracy.
Technical data-Master meter ZCM17 48
Application : Master meter dedicated to calibration of custody transfer volume measuring equipments
Max. Operating flowrate m3.h-L/mn-USGPM : 48-800-210
Min Operating flowrate m3/h-L/mn-USGPM : 4.8-80-21
Measured parameters : Operating volume base volume (only for ZCM 17E)
Measured liquids : Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester oils
Connections : Flanges or dry coupling*2×3 m hose*
Meter :
Diameter : 2″
PD meter : ZC17-48
Version ZCM 17 IM
| Register | Mechanical register (VR). Total volume with reset 5 digits Total volume without reset 8 digits |
| Volume display | Operating volume |
| Flowrate display | Included with IDI module L/min or m3/h |
| Calibration curve | 7 flowrates values with 2 values per flowrate. One curve per operating viscosity |
| Calculation of reference volume | Manual calculation |
| Temperature measurement | Local display |
| Drainage equipment | Manual drainage pump with purge valve and 2 release valves |
| Trolley | Calibration device mounted on chassis with 4 pivoting wheels |
| Operating Conditions | |
| Pressure | 10 bar max |
| Viscosity | 50 cSt max |
| Liquid temperature | 10°C to +80°C |
| Ambient temperature | Standard -25°C to+55°C – option : -40°C to + 55°C |
| Metrological Performances | |
| Volume accuracy | < ±0.1% |
| Volume repeatability | < ± 0,02% |
| Temperature accuracy | < ±0.5°C |
Version ZCM 17 E
| Register | Electronic register (Equalis). Total volume : 6 digits Secure storage of ZCM 17 calibration curves. Calculation of reference volume |
| Volume display | Operating volume, base volume |
| Flowrate display | Included |
| Calibration curve | 7 flowrate values with 2 values per flow rate. One per operating viscosity |
| Calculation of reference volume | Automatic calculation |
| Temperature measurement | Pt 100 |
| Pressure measurement | Local display |
| Drainage equipment | Manual drainage pump with purge valve and 2 release valves |
| Operating conditions | |
| Pressure | 10 bar max |
| Viscosity | 50 cSt max |
| liquid temperature | Standard : -25°C to +55°C-Option : -40°C to +55°C |
| Metrological Performances | |
| Volume accuracy | < ±0.5% with linearization |
| Volume repeatability | < ±0.02% |
| Temperature accuracy | < ±0.5°C |