Master Meter SATAM ZCN17 48

The Satam “Master Meter” product range is dedicated range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard that can be used regularly to check and calibrate measuring instruments or measuring systems. Within minimal dimensions, it can easily be moved to several different sites without the requirement for lifting tools.

Equipped with an Equalis electronic register that ensures linearization of measurements, it can be used with liquids of various viscosities without loss of accuracy.

Sector of application
Oil depots

For oil product reception and loading stations for tank truck tank car and ships

Hydrocarbon transportation
Distribution of fuel oil or fuel by road tankers

Aircraft refueling
Aircraft dispensers and aircraft fueling tankers

Army
Depot supplies and loading of trucks

Transport companies
Refuelling of lecomotives, truck and public transport

Marine applications
Refuelling of ships

Mining Sites
Refuelling of truck or site machinery

Desin of the master meter
Robust construction
Positive displacement meter with moving blades

Modular design
Available with mechanical or electronic register

Calibration for different viscosities
Supplied with one calibration certificated per each operating viscosity

Key point
Compact design

Calibration device of reduced weight and dimensions.
Possibility to move the ZCM 17 to different sites without the requirement

Self poered technology
Functioning of the mechanical register version without any power supply

Modular design
Wide range of accessories to create your customized calibration device
Can be intalled in a trolley as mobile calibration equipment

Stability and accuracy of measurement

Stable and accurate volume measurement without any influence of installation position
Flow meter manifold separated from measurement chamber to eliminate any posibble influence of external mechanical stressed on measurement accuracy.

Technical data-Master meter ZCM17 48

Application : Master meter dedicated to calibration of custody transfer volume measuring equipments
Max. Operating flowrate m3.h-L/mn-USGPM : 48-800-210
Min Operating flowrate m3/h-L/mn-USGPM : 4.8-80-21
Measured parameters : Operating volume base volume (only for ZCM 17E)
Measured liquids : Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester oils
Connections : Flanges or dry coupling*2×3 m hose*
Meter :
Diameter : 2″
PD meter : ZC17-48

Version ZCM 17 IM

RegisterMechanical register (VR). Total volume with reset 5 digits Total volume without reset 8 digits
Volume displayOperating volume
Flowrate displayIncluded with IDI module L/min or m3/h
Calibration curve 7 flowrates values with 2 values per flowrate. One curve per operating viscosity
Calculation of reference volumeManual calculation
Temperature measurementLocal display
Drainage equipmentManual drainage pump with purge valve and 2 release valves
TrolleyCalibration device mounted on chassis with 4 pivoting wheels
Operating Conditions 
Pressure 10 bar max
Viscosity50 cSt max
Liquid temperature10°C to +80°C
Ambient temperatureStandard -25°C to+55°C – option : -40°C to + 55°C
Metrological Performances 
Volume accuracy< ±0.1%
Volume repeatability< ± 0,02%
Temperature accuracy< ±0.5°C

Version ZCM 17 E

RegisterElectronic register (Equalis). Total volume : 6 digits Secure storage of ZCM 17 calibration curves. Calculation of reference volume
Volume displayOperating volume, base volume
Flowrate displayIncluded
Calibration curve7 flowrate values with 2 values per flow rate. One per operating viscosity
Calculation of reference volumeAutomatic calculation
Temperature measurementPt 100
Pressure measurementLocal display
Drainage equipmentManual drainage pump with purge valve and 2 release valves
Operating conditions  
Pressure10 bar max
Viscosity50 cSt max
liquid temperatureStandard : -25°C to +55°C-Option : -40°C to +55°C
Metrological Performances 
Volume accuracy< ±0.5% with linearization
Volume repeatability< ±0.02%
Temperature accuracy< ±0.5°C