Control valves-C221 altitude valves pilot operated-bottom-fill version-pressure sustaining functionDetail Product :Same control valves as C201 but fiited with a preset ipstream sustaining function exists in top-fill or bottom-fill versions. Applications and general chracteristics : It prevents from overflowing and maintains a constant level in the tank tahanks to the and guarantees a minimum up stream pressure Openings and closing are you very proggressive (a few centieters from te required level) This type of valve should be used when the supply … Continue reading “SOCLA TYPE C221”
SOCLA TYPE C707
Posted on Categories SOCLA Leave a comment on SOCLA TYPE C707Contro valves-C707 altitude valves float operated Detai Product :Regulated contents of a tank by volume of water using float regulation (not included) : closes at a preset high water level and opens at a given low water level. Katalog Socla Type 707 DN 1.5 (F/F) 40 and 50 65 80 100 125 150 200 250 300
SOCLA TYPE 302
Posted on Categories SOCLA Leave a comment on SOCLA TYPE 302Foot Valve-302 pumping, clear water Detail Produck :Pressure PFA/PS in barCasing : GJL cast iron epoxy coatedClosing system : DN 50 and 65 in bronze, other DN in cast iron with steam in bronzeGuiding system : DN 50 in bronze other in cast iron with bronze ringSeal : EPDMStrainer : galvanised steel DN DN PFA PS Cat Ref UV “ mm water L1 L2 G1 G2 2 50 16 16 16 x x 4.3 … Continue reading “SOCLA TYPE 302”
SOCLA TYPE 302P
Posted on Categories SOCLA Leave a comment on SOCLA TYPE 302PFoot valve-302P pumping, clear water Detail Product :Pressure PFA/PS in bar Ө 80°Casing : GJL cast iron epoxy coatedClosing System : Same as valves type 302-102Spring : Stainless SteelSeal : EPDM- Strainer : PP (Polypropylene) DN DN PFA PS Cat Ref UV “ mm water L1 L2 G1 G2 2 50 16 16 16 x x 4.3 149B 2746 1 2 1/2 65 16 16 16 x x 4.3 149B 2747 1 3 65 … Continue reading “SOCLA TYPE 302P”
Water Meter Louis Victor 3/4 Inch
Posted on Categories Water Meter Louis Victor Leave a comment on Water Meter Louis Victor 3/4 InchFeature : Vacuum sealed register ensure a clear presentation in a long term service Selected high quality materials for steady and realible characteristic Without removing the meter from the pipeline for maintenance and replacement Maximum conditions : In the lower zone rom Q1 inclusive up to but excluding Q2 is ±5% In the upper zone from Q2 inclusive up to nd including Q4 is ±2% Working Temperature : Water temperature 0°C ≤ T ≤ 30°C (for cold water meter) 0°C … Continue reading “Water Meter Louis Victor 3/4 Inch”
Water Meter Louis Victor 3 Inch
Posted on Categories Water Meter Louis Victor Leave a comment on Water Meter Louis Victor 3 InchFeature : Vacuum Sealed register ensures A clear presentation in a long term service Selected high quality materials for steady and reliable chracteristic Without removing the meter fro the pipeline for maintenance and replacement Maximum Permission Error In the lowerzone rom Q1 inclusive up to but excluding Q2 is ±5% In the upper zone from Q2 inclusive up to and including Q4 is ±2% Working Conditions : Water temperature 0°C ≤ T ≤ 30°C (for cold water meter) 0°C ≤ … Continue reading “Water Meter Louis Victor 3 Inch”
Water Meter Louis Victor 4 Inch
Posted on Categories Water Meter Louis Victor Leave a comment on Water Meter Louis Victor 4 InchFeature : Vacuum sealed register ensures A clear presentation in a long term service Selected high quality materials for steady and reliable characteristic Without removing the meter fro the pipeline for maintenance and replacement Maximum Permissin Error In the lower zone rom Q1 inclusive up to but excluding Q2 is ±5% In the upper zne from Q2 inclusive up to and including Q4 is ±2% Working Condition : Water temperature 0°C ≤T ≤30°C (for cold water meter) 0°C ≤T ≤90°C … Continue reading “Water Meter Louis Victor 4 Inch”
Water Meter Louis Victor 1/2 Inch
Posted on Categories Water Meter Louis Victor Leave a comment on Water Meter Louis Victor 1/2 InchFeature : Vacuum Sealed Register Ensures A Clear Presentation In A long Term Service Selected High Quality Materials for Steady And Reliable Chracteristic Without Removing The Meter From The Pipeline For Maintenance And Replacement Maximum Permission Error In the lower zone rom Q1 inclusive up to but excluding Q2 is ±5% In the upper zone from Q2 Inclusive up to and Including Q4 is ±2% Working Conditions ; Water temperature 0°C ≤ T ≤ 30°C (for cold water meter) 0°C … Continue reading “Water Meter Louis Victor 1/2 Inch”
Water Meter Louis Victor 2 Inch
Posted on Categories Water Meter Louis Victor Leave a comment on Water Meter Louis Victor 2 InchFeature : Vacuum sealed register ensures a clear presentation in a long term service Selected high quality materials for steady and reliable characteristic Without removing the meter from the pipe line for maintenance and replacement Maximum Permission Error In the lower zone rom Q1 inclusive up to but excluding Q2 is ±5% In the upper zone from Q2 inclusive up to and including Q4 is ±2% Working Condition : Water temperature 0°C≤ to ≤ 30°C (for cold water meter) 0°C≤ … Continue reading “Water Meter Louis Victor 2 Inch”
Water Meter Louis Victor 1 Inch
Posted on Categories Water Meter Louis Victor Leave a comment on Water Meter Louis Victor 1 InchFeature : Vacuum sealed register ensures a clear presentation in a long-term service Selected high quality materials for steady and reliable characteristic Without removing the meter fro the pipeline for maintenance and replacement Maximum Permission Error In the lower zone rom Q1 inclusive up to but excluding Q2 is ±5% In the upper zone from Q2 inclusive up to and including Q4 is ±2% Working Condition : Water temperature 0°C≤ to ≤30°C (for cold water meter) 0°C≤ 90°C(for hot water … Continue reading “Water Meter Louis Victor 1 Inch”
