PD Meter SATAM ZC17 24

Positive Diplacement Meter
Model ZC 17

The Satam Positive Diplacement Meter (PD Meter) is a system with freely-moving blades used to measure petroleum product such as fuels, bio-fuels and refined liquid hydrocarbon and nono corrosive chemicals.
Its simple design with only two pairs of blades and one moving rotor makes it exceptionally robust nd allows the user to make significatnt saving in maintenance costs.

Sector of Application :
Oil Depots
For oil product reception and loading stations for tank truck tank car and ships

Hydrocarbon transportation
Distribution of fuel oil or fuel by road tanker

Aircraft Refuelling
Aircraft dispensers fuel oil by road tanker

Army
Depot supplies and loading of trucks

Transport companies
Refueling of locomotives, trucks and public transport coaches

Marine applications
Refuelling of ships

Mining sites
Refuelling of struck or site machinery

Key points
Reduced pressure loss
0.3 to 0,5 bar at maxium flow rate

Low maintenance costs
Simple and robust design with mechanical components interchangeable between the different models

Stability of measurement
Accuracy of measurement guaranteed over a period of many years without any drift in the calibration curve

Modular design
Wide range of accessories for performing customized measurement applications

Robust construction
Flowmeter manifold is seperated from measurement chamber to eiminate any posibble influence of external mechanical stress on measurement accuracy.

Technical data-PD meter ZC17 24

Application Custody transfer metering of liquid hydrocarbon
Max. Flowrate (m3/h-L/mn-USGPM)24-400-105
Min. Flowrate (m3/h-L/mn-USGPM)2.4-40-10.5
Connection 
DN2″
Flanges (standard)Standard Satam
Flanges (option)ASA 150 RF
Materials 
ManifoldAluminium
CasingDuctile iron or Ni resist iron
Front and back coverCarbon steel with protective coating
Rotor-Blades-GasketsAluminium-Graphite-Viton (option nitrile)
Operating conditions 
Max. Pressure (operation)10 bar-150 PSI
Max. pressure (EC/MID certificate)6 bar (gasoline, kerosene) 8 bar (diesel oil, ethanol)
Max. viscosity MID : 20mm2/s (cSt)-operation : 800 mm2/s (cSt)
Liquid temperature-10°C to +55°C
Ambient temperatureStandard -25°C to +55°C-Option : -40°C to +55°C
Pressure drop at max flowrate, 3.7 mm2/s (cSt)0.45
Internal construction Cyclic volume (L-USG)0.40-0.10
Metrological Performances 
Accuracy< 0.15%/ option < 0.1 for 10:1 measuring range
Repeatability< 0.02%