APPLICATION
- Measurement of differential pressure or of two different pressure applied in refrigeration plants or compressors
- Simulataneous measurement of the vapour pressure and the resulting vapour temperature
- For gaseous and liquid aggresive media that are not highly viscous or crystallising, also in aggresive ambience
Special Features
- Differential pressure with moving dial
- Design optionally with duplex scale
- With liquid-filled case for damping in applications with high dynamic pressure loads or vibrations and avoiding condensation water
- Combined pressure and temperature scales, as duplex, triplex or quadruple scales for all common refrigerants
Description Product
Design
Two independent measuring system, parallel entries in line
Nominal Size in mm
80,100
Accuracy class
1.6
Scale ranges
0…..2.5 to 0…..60 bar -1….0…..+25 bar
-1…..0…..+12 bar -1…….0…..+30 bar
-1…..0….. +15 bar -1……0…….+35 bar
-1…..0……+ 16 bar -1…..0……=40 bar
Other scale ranges on request
In order to ensure a good readability, the differential pressure should be no less than 1/6 of the full scale value.
Pressure limitation
Steady : Full scale value
Fluctuating : 0.9 x full scale value
Short time : 1.3 x full scale value
Permissible temperature
Ambient ; 0….+60 °C
Medium : +100°C maximum
Temperature effect
When the temperature of the measuring system deviate from the reference temperature
(+20°C) : max ±04 %/10 K of full scale value