Description
Design
EN 837-1
Nominal size in mm
63, 80, 100
Accuracy class
NS 63, 80 : q.6
NS 100 : 1.0
Scale ranges
0….0.6 to 0…1.000 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
NS 63, 80, 80 : Steady : 3/4 x full scale value
Fluctuating : 2/3 x full scale value
Short time : Full scale value
NS 100 : Steady : Full scale value
Fluctuating : 0.9 x full scale value
Short time : 1.3 x full scale value
Permissible effect
When the temperature of the measuring system deviates from the reference temperature (+20°C) : max ±0.4%/10 K of the span.
Application
- For measuring points with high dynamic pressure loads or vibrations
- For gaseous and liquid media that are not highly viscous or crystallising and will not attack copper parts
- Mining
- Hydraulics
- Shipbuilding
Special Features
- Vibration and shock resistant
- Especially robust design
- NS 63 and 100 with Germanischer Lioyd Gosstandart approval
- Scale range up to 0….1.000 bar