Description
Design
EN 837-1
Nominal size in mm
160
Accuracy class
0.6
Scale ranges
0….0.6 to 0….60 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Adjustment medium
≤ 25 bar : Gas
>25 bar : Liquid
Pressure limitation
Steady : Full scale value
Fluctuating : 0.9 x full scale value
Short time : 1.3 x full scale value
Permissible temperature
Ambient : -40…+60°C
Medium : +80°C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20°C) max. ±0.4%/ 10 K of full scale value
Ingress protection
IP54 per IEC/EN 60529
Application
- For gaseous and liquid media that are not highly viscous or crystallising and will not attack alloy parts
- Precision measurement in laboratories
- High accuracy pressure measurement
- Testing of industrial type pressure gauges
Special Features
- Knife edge pointer for optimal accuracy of reading
- Precise movement with waer part of argentan
- Scale ranges up to 0…..600 bar