Submersible Pompa Pedrollo MC 10/50-F DOUBLE CHANNEL

Specification Product :

Single Phase (MCm 10/50-F0), Three Phase (MC 10/50-F)

Power :

KW : 0.75

HP : 1

Flow Rate (Q) = m3/h : Total manometric head = metres

0 : 12

3 : 10.7

6 : 9.7

9 : 8.7

12 : 7.8

15 : 6.8

18 : 5.9

21 : 5

24 : 4

27 : 3

30 : 2

Flow Rate (Q) = l/min : Total manometric head = metres

0 : 12

50 : 10.7

100 : 9.7

150 : 8.7

200 : 7.8

250 : 6.8

300 : 5.9

350 : 5

400 :4

450 : 4

500 : 2

Ports

Outlet : 2″

Solid passage : ø 50 mm

Berat : Single Phase : 14.5 kg ø

Three phase : 13.2 kg

Performance Range

  • Flow rate up to 650 l/min (39 m3/h)
  • Head up to 14 m

Appication Limits

  • 5 m maximum immersion depth
    (with a sufficiently long power cable)
  • Maximum liquid temperature +40°C
  • Passage of solids
    – Up to ø 40 mm for VX/35-N
    – Up to ø 50 mm for VX/50-N
  • Minimum immersion depth for continuous service
    – 280 mm for VX/35-N
    – 300 mm For VX/50-N

Construction and Safety Standard

Power cable length :
– 5 m for VX8-10/35-N, VX8-10/50-N
– 10 mm for VX15/35-N, VX15/50-N

  • Float switch for single-phase versions

EN 60335-1

IEC 60335-1

CEI 61-150

EN 60334-1

IEC 60334-1

CEI 2-2

Certifications

Company with management system certified DNV ISO 900 : Quality

ISO 14001 : Environment

Installation and Use

VX pumps sre recommended for domestic, civil and industrial applications in all cases where the water contains suspended solids to ø 50 mm, for example groundwater, surface waterm filthy and dirty water.

They are for example suitable for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal.

These pumps distinguish themselves for their reliability, which can be appreciated under automatic operating conditions in fixed installations.

Patents-Trade-Marks-Models

  • Patent pending n, BO2015Aooo116

Options Available On Request

  • VX 8-10 pumps with a 10 m power cable

NB : Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor

Applications

  • Single phase pumps without float switch
  • Other voltages or 60 Hz frequency

Leave a Reply