Wolman type water meter can be used for flow rates higher than Qn 15 m3/h. They are thereby distinguished by ensuring an especially low head loss, even with high flow rates.
They newly developed measuring insert with a special construction of the turbine where the water flows through, guarantees a high measuring accuracy and long term stability of the measuring results. Large number at all times.
Similar to multi-jet meters, Wolman meters measure the velocity of the water flowing through with the help of a turbine. The volume is mechanically calculated, through the known volume of the measuring chamber, and indicated with the roller counters in cubic meters. The unique form the “paddle wheels” enable the Wolman meters to cover a very large measuring range with especially low head loss. Aside from their construction for high flow rates, they also reliably start measuring with small water quantities.
Active or passive sensors are available for communication with pulse counting modules or automation and control systems.Inductive NAMUR, optical and reed sensors can be retrofitted without damaging the calibration seal. Active sensors have a pulse value, depending on the meter sizes, of either 1 or 10 L/lmp. Reed sensors have a pulse value 0f 100 L/imp. Up to 10 m3/imp, depending on the meter size.
Wolman Meter With Parallel Turbine Shaft
Wolman parallel type meters are always used when high flow rates with a relative constant flow rate profile are to be measured. Through its robust construction they not only are capable of covering a large measuring range, but the measuring accuracy is also long-term stable.
The hydrodynamic optimize turbine is reliably operated already at small flow rates and “upwards” it has enough powder reserves to reliably measures flow rate peaks. Especially strong bearing with low frition guarantee a long life of the meter.
Reed sensors, optical and inductive -NAMUR sensor can always be retrofitted without damaging the calibration seal. Then the meter can be integrated with data communication or automation and control system in a simple and flexible way.
Performance Characteristics in Overview
- Low starting flow, high overload security
- Wide measuring range
- Removable measuring insert
- Low head loss
- Hydraulic bearing relieve for long term measuring stability
- Retrofitted with active and passive pulsers
- Metal protective cover serially, plastic optional
- Evacuated counter protected from condensation
- Dry dial counter with large number rollers simplifies the readability
- For cold water up 30°C, with security up to 50°C
- For horizontal, vertical and inclined installation position
- High pressure model PN25/40 upon request
Technical Data :
Diameter Flow Qn | 150 m3/h |
Nominal Diameter (DN) | 150 mm |
Overal Length (L) | 300 mm |
Metrological class | B |
Maximum Flow (short-term) Qmax | 350 m3/h |
Maximum Flow (Constant) | 250 m3/h |
Transitional Flow | 12 m3/h |
Minimum Flow Qmin | 3.5 m3/h |
Flow rate with 0.1 bar head loss | 2000 m3/h |
Head loss at Qmax | 0.2 bar |
Display range | min (2) max (9.999.999 m3) |
Maximum temperature | 50°C |
Operating pressure, max (PN) | 16 bar |
Height (H) | 200 mm |
Flange diameter (D) | 165 mm |